Copyright
©2014 Baishideng Publishing Group Inc.
World J Gastrointest Endosc. May 16, 2014; 6(5): 193-199
Published online May 16, 2014. doi: 10.4253/wjge.v6.i5.193
Published online May 16, 2014. doi: 10.4253/wjge.v6.i5.193
Table 2 Metrics analysed for discriminatory ability
Kinect metrics | Experienced endoscopist | Novice | Levene’s test | P value |
Percentage of time with hands closer than 25 cm (%) | 7 | 23 | 0.048 | 0.02 |
Distance between hands (cm) | 45 | 37 | 0.09 | 0.01 |
Angle of shoulders (degrees) | 17 | 20 | 0.95 | 0.38 |
Right hand below z-line (cm) | 25 | 36 | 0.95 | 0.01 |
Mean distance shoulder-hand (cm) | 31 | 31 | ||
Left hand above z-line (cm) | 6 | 15 | 0.03 | 0.005 |
Mean distance: shoulder-hand (cm) | 32 | 31 | ||
Left elbow (degrees) | 91 | 92 | 0.86 | 0.81 |
Right elbow (degrees) | 144 | 140 | 0.55 | 0.55 |
Height participants (cm) | 39 | 30 | 0.08 | 0.02 |
Compared to coordinates |
- Citation: Svendsen MB, Preisler L, Hillingsoe JG, Svendsen LB, Konge L. Using motion capture to assess colonoscopy experience level. World J Gastrointest Endosc 2014; 6(5): 193-199
- URL: https://www.wjgnet.com/1948-5190/full/v6/i5/193.htm
- DOI: https://dx.doi.org/10.4253/wjge.v6.i5.193