Copyright
©2013 Baishideng Publishing Group Co.
World J Gastrointest Endosc. Jul 16, 2013; 5(7): 323-331
Published online Jul 16, 2013. doi: 10.4253/wjge.v5.i7.323
Published online Jul 16, 2013. doi: 10.4253/wjge.v5.i7.323
Pink | Red center | Red | Red-point | Cherry-red | Black-brown | |||||||
mosaic-like pattern | mosaic-like pattern | mosaic-like pattern | lesions | spots | spots | |||||||
Diagnosis | PH | PHG | PH | PHG | PH | PHG | PH | PHG | PH | PHG | PH | PHG |
Sensitivity | 26.00% | 52.17% | 16.00% | 34.78% | 6.00% | 13.04% | 28.00% | 47.83% | 22.00% | 39.13% | 2.00% | 4.35% |
Specificity | 90.00% | 92.21% | 100.00% | 100.00% | 100.00% | 100.00% | 92.00% | 90.91% | 98.00% | 96.10% | 98.00% | 98.70% |
PPV | 72.22% | 66.67% | 100.00% | 100.00% | 100.00% | 100.00% | 77.78% | 61.11% | 91.67% | 75.00% | 50.00% | 50.00% |
NPV | 54.88% | 86.59% | 54.35% | 83.70% | 51.55% | 79.38% | 56.10% | 85.37% | 55.68% | 84.09% | 50.00% | 77.55% |
Accuracy | 58.00% | 83.00% | 58.00% | 85.00% | 53.00% | 80.00% | 60.00% | 81.00% | 60.00% | 83.00% | 50.00% | 77.00% |
False negative | 37.00% | 11.00% | 42.00% | 15.00% | 47.00% | 20.00% | 36.00% | 12.00% | 39.00% | 14.00% | 49.00% | 22.00% |
False positive | 5.00% | 6.00% | 0.00% | 0.00% | 0.00% | 0.00% | 4.00% | 7.00% | 1.00% | 3.00% | 1.00% | 1.00% |
Significance | P = 0.033 | P < 0.001 | P = 0.003 | P < 0.001 | P = 0.121 | P = 0.011 | P = 0.009 | P < 0.001 | P = 0.002 | P < 0.001 | P = 0.753 | P = 0.358 |
Reliability (α) | 0.5691 | 0.5691 | 0.7272 | 0.7272 | 0.0792 | 0.0792 | 0.7522 | 0.7522 | 0.7532 | 0.7532 | 0.4081 | 0.4081 |
- Citation: de Macedo GFS, Ferreira FG, Ribeiro MA, Szutan LA, Assef MS, Rossini LGB. Reliability in endoscopic diagnosis of portal hypertensive gastropathy. World J Gastrointest Endosc 2013; 5(7): 323-331
- URL: https://www.wjgnet.com/1948-5190/full/v5/i7/323.htm
- DOI: https://dx.doi.org/10.4253/wjge.v5.i7.323