Tham et al 1998 | Bueno et al 2003 | Togawa et al 2008 | Rogart et al 2008 | Ridtitid et al 2010 | Cho et al 2011 | |
No. of SEMS occlusion | 44 | 34 | 40 | 27 | 32 | 77 |
Type of initial SEMS (patients) | ||||||
Covered SEMS | 0 | 0 | 0 | 4 | 10 | 47 |
Uncovered SEMS | 44 | 34 | 40 | 23 | 22 | 30 |
Initial stent patency (d): total | 118a | 60-150a | ||||
Covered SEMS | NA | NA | NA | NA | NA | 189 |
Uncovered SEMS | 102 | 125 | 153 | NA | NA | 132 |
Type of second drainage (patients) | ||||||
Covered SEMS | 0 | 0 | 26 | 9 | 4 | 40 |
Uncovered SEMS | 19 | 4 | 7 | 5 | 10 | 26 |
Plastic stent | 20 | 24 | 7 | 11 | 1 | 11 |
Mechanical cleaning | 5 | 6 | 0 | 2 | 0 | 0 |
PTBD | 0 | 0 | 0 | 0 | 7 | 0 |
Second drainage patency (median, d) | ||||||
Covered SEMS | NA | NA | 220e | 214b | NA | 138c |
Uncovered SEMS | 75 | 192 | 141e | 54 | 100 | 109 |
Plastic stent | 90 | 90 | 58e | 66 | 60 | 88 |
Mechanical cleaning | 34 | 21 | NA | 43 | NA | NA |
PTBD | NA | NA | NA | NA | 75 | NA |
Survival (d) | ||||||
Covered SEMS | NA | NA | NA | 227 | NA | 440d |
Uncovered SEMS | 70 | NA | NA | 389 | 230f | 243 |
Plastic stent | 98 | NA | NA | 188 | 130 | 296 |
Mechanical cleaning | 34 | NA | NA | 194 | NA | NA |
PTBD | NA | NA | NA | NA | 150 | NA |