Copyright
©The Author(s) 2024.
World J Gastrointest Endosc. Dec 16, 2024; 16(12): 668-677
Published online Dec 16, 2024. doi: 10.4253/wjge.v16.i12.668
Published online Dec 16, 2024. doi: 10.4253/wjge.v16.i12.668
PECS group | Non-PECS group | |
Intraprocedural perforation or penetration/number of patients in each group | 1/30 | 5/172 |
ESD procedure performed by trainees/number of patients in each group | 1/30 | 5/172 |
Peak CRP (mg/dL), mean ± SD | 4.11 ± not applicable | 1.56 ± 1.42 |
Duration of hospitalization (days), mean ± SD | 6 ± not applicable | 6.2 ± 2.2 |
- Citation: Ochi M, Yamamoto A, Suematsu S, Fukuda K, Morishige K, Oka Y, Ishikawa Y, Ueyama S, Hiroshima Y, Omae Y, Kusano F, Kamoshida T. High Joule heat as a risk factor for post-endoscopic submucosal dissection electrocoagulation syndrome: A multicenter prospective study. World J Gastrointest Endosc 2024; 16(12): 668-677
- URL: https://www.wjgnet.com/1948-5190/full/v16/i12/668.htm
- DOI: https://dx.doi.org/10.4253/wjge.v16.i12.668