Case Control Study
Copyright ©The Author(s) 2022.
World J Gastrointest Endosc. Sep 16, 2022; 14(9): 524-535
Published online Sep 16, 2022. doi: 10.4253/wjge.v14.i9.524
Table 5 Diagnostic accuracy of conventional B-mode endoscopic ultrasound and qualitative and quantitative endoscopic ultrasound elastography analysis for malignancy in the associated lymph nodes (n = 43)
Conventional B-mode EUS
EUS-elastography qualitative analysisEUS-elastography quantitative analysis
Size
Shape
Border
Density
SR ≥ 14.01
SR ≥ 155.02
Sensitivity (%)59.150.059.131.868.190.94.5
Specificity (%)42.952.461.985.738.128.695.2
PPV (%)52.052.461.970.053.651.450.0
NPV (%)50.050.059.154.653.375.048.8
Accuracy (%)51.251.260.558.153.560.448.8

  • Citation: Puga-Tejada M, Del Valle R, Oleas R, Egas-Izquierdo M, Arevalo-Mora M, Baquerizo-Burgos J, Ospina J, Soria-Alcivar M, Pitanga-Lukashok H, Robles-Medranda C. Endoscopic ultrasound elastography for malignant pancreatic masses and associated lymph nodes: Critical evaluation of strain ratio cutoff value. World J Gastrointest Endosc 2022; 14(9): 524-535
  • URL: https://www.wjgnet.com/1948-5190/full/v14/i9/524.htm
  • DOI: https://dx.doi.org/10.4253/wjge.v14.i9.524