Copyright
©The Author(s) 2022.
World J Gastrointest Endosc. Jun 16, 2022; 14(6): 354-366
Published online Jun 16, 2022. doi: 10.4253/wjge.v14.i6.354
Published online Jun 16, 2022. doi: 10.4253/wjge.v14.i6.354
Ref. | Design | Technical success (%) | Adverse events | Recurrence | Needle size | Treatment |
Robb et al[61], 2012 | Case Report | 100 | None | None after 5 mo follow-up | 19G | Psuedoaneurysm embolization |
Gamanagatti et al[62], 2015 | Case Report | 100 | None | Recurrence; asymptomatic | 22G | Thrombin injection 300-500 units |
Mann et al[27], 2017 | Case Report | 100 | Not reported | None after 2 wk follow-up | 19G | 5 coils of 10 mm size were placed, 3000 units of thrombin injected |
Jhajharia et al[63], 2018 | Case Report | 100 | Not reported | None in all three patients | Not reported | 1000 units of thrombin |
Gunjan et al[63], 2018 | Case Report | 100 | Not reported | None after 9 mo follow-up | 19G | 3 mL of undiluted N-butyl-cyanoacrylate |
Sharma et al[65], 2019 | Case Report | 100 | None | Full obliteration on 2-wk follow-up | 19G | Five 10 mm coils placed, 6 mL of 3000 units of thrombin injected in six boluses of 500 units each |
- Citation: Fugazza A, Khalaf K, Colombo M, Carrara S, Spadaccini M, Koleth G, Troncone E, Maselli R, Repici A, Anderloni A. Role of endoscopic ultrasound in vascular interventions: Where are we now? World J Gastrointest Endosc 2022; 14(6): 354-366
- URL: https://www.wjgnet.com/1948-5190/full/v14/i6/354.htm
- DOI: https://dx.doi.org/10.4253/wjge.v14.i6.354