Copyright
©The Author(s) 2022.
World J Gastrointest Endosc. Apr 16, 2022; 14(4): 226-234
Published online Apr 16, 2022. doi: 10.4253/wjge.v14.i4.226
Published online Apr 16, 2022. doi: 10.4253/wjge.v14.i4.226
Table 2 Endoscopist, overall, and average sessile serrated adenomas detection rates with corresponding colonoscopy volumes during standard definition colonoscopy and high definition colonoscopy
Endoscopist | Standard definition | High definition | Δ | P value (α < 0.05) | ||
Eligible colonoscopies | SSADR | Eligible colonoscopies | SSADR | |||
1 | 166 | 4.22% | 229 | 2.18% | -2.03% | 0.24604 |
2 | 303 | 2.97% | 279 | 4.66% | 1.69% | 0.28462 |
3 | 82 | 0.00% | 124 | 2.42% | 2.42% | 0.1556 |
4 | 171 | 5.26% | 37 | 5.41% | 0.14% | 0.9681 |
5 | 63 | 0.00% | 51 | 3.92% | 3.92% | 0.11184 |
6 | 135 | 1.48% | 98 | 4.08% | 2.60% | 0.21498 |
7 | 125 | 1.60% | 76 | 2.63% | 1.03% | 0.61006 |
8 | 410 | 6.34% | 356 | 12.08% | 5.74% | 0.0056 |
9 | 238 | 1.68% | 97 | 6.19% | 4.50% | 0.0278 |
10 | 191 | 2.62% | 161 | 7.45% | 4.84% | 0.03486 |
11 | 128 | 3.91% | 137 | 4.38% | 0.47% | 0.8493 |
Overall | 2012 | 3.43% | 1645 | 5.96% | 2.53% | 0.00028 |
Average | 182.91 | 2.73% | 149.54 | 5.04% | 2.30% | 0.00849 |
- Citation: Sehgal A, Aggarwal S, Mandaliya R, Loughney T, Mattar MC. Improving sessile serrated adenoma detection rates with high definition colonoscopy: A retrospective study. World J Gastrointest Endosc 2022; 14(4): 226-234
- URL: https://www.wjgnet.com/1948-5190/full/v14/i4/226.htm
- DOI: https://dx.doi.org/10.4253/wjge.v14.i4.226