Table 4 The areas under the receiver operating characteristic curves and optimal cutoff values for s-Lipase and s-Amylase based on the presence/absence of post-endoscopic retrograde cholangiopancreatography pancreatitis in the early stage after endoscopic retrograde cholangiopancreatography
s-Lip | s-Amy | P-value1 | |
AUC (95%CI) | 0.908 (0.880-0.940) | 0.880 (0.846-0.915) | 0.023 |
Optimal cutoff value (U/L) | 342 | 171 | ― |
Sensitivity | 0.859 | 0.859 | ― |
Specificity | 0.867 | 0.763 | ― |
Positive predictive value | 0.405 | 0.277 | ― |
Negative predictive value | 0.981 | 0.979 | ― |
- Citation: Tadehara M, Okuwaki K, Imaizumi H, Kida M, Iwai T, Yamauchi H, Kaneko T, Hasegawa R, Miyata E, Kawaguchi Y, Masutani H, Koizumi W. Usefulness of serum lipase for early diagnosis of post-endoscopic retrograde cholangiopancreatography pancreatitis. World J Gastrointest Endosc 2019; 11(9): 477-485