Case Control Study
Copyright ©The Author(s) 2018.
World J Gastrointest Endosc. Oct 16, 2018; 10(10): 294-300
Published online Oct 16, 2018. doi: 10.4253/wjge.v10.i10.294
Table 3 Regression analysis of the time between dilation (d) for patients who underwent lumen apposing metal stent placement
R2InterceptCoefficientFP
Mean overall68.3%220.3-27.88.60.04
Mean female16.9%192-17.40.80.41
Mean male96.1%250-39.399.30.001
Mean surgical62.2%96.2-63.36.50.06
Mean nonsurgical62.8%188.3-19.46.70.06