Table 2 Studies describing different quantitative molecular methods
Ref.Year of publicationMethod of quantitationDetection limit
Garson et al[58]2005FRET based real time PCR assaySn at 95% detection level was 24.2 IU/mL
Welzel et al[59]2006Novel real time PCRSn at 95% detection level was 56 IU/mL
Mazet-Wagner et al[60]2006Real time PCR assay to detect total HBV DNA and cccDNA from serum and peripheral blood mononuclear cells27 IU/mL
McCormick et al[61]2006Procleix Ultrio Assay (Multiplex PCR) to detect HIV 1, HCV RNA and HBV DNA simultaneouslySp ≥ 99.5%, Sn is > 95% with detection limit for HBV DNA of 15 IU/mL
Cai et al[62]2008Real time fluorogenic Loop Mediated Isothermal Amplification (RtF-LAMP)At 95% detection level 210 copies/mL
Paraskevis et al[63]2010New ultrasensitive in house real time PCR assaySn at 95% and 50% detection level: 22.2 IU/mL and 8.4 IU/mL
Chevaliez et al[64]2010v2.0 of the CAP/CTM assayHighly Sn, could even detect 6.25 IU/mL HBV DNA; Sp is 99%, Intra-assay and interassay coefficients of variation ranged from 0.21% to 2.67% and from 0.65% to 2.25%, respectively
Sun et al[65]2011Duplex real-time PCR assay using two sets of primers/probes and a specific armored DNA as internal controlDetection limit 29.5 IU/mL; Sp 100%
Cha et al[66]2013ExiStation HBV diagnostic system9.55 IU/mL
Yang et al[67]2014Colorimetric PCR with DNA zyme containing probeBroad range of linearity and high sensitivity