Systematic Reviews
Copyright ©The Author(s) 2025.
World J Hepatol. Feb 27, 2025; 17(2): 100033
Published online Feb 27, 2025. doi: 10.4254/wjh.v17.i2.100033
Table 4 Point-shear wave elastography diagnostic efficacy (area under the receiver operating characteristic curves for fibrosis detection)
Ref.
Number of patients
Disease/diagnose
Diagnostic method
Fibrosis stage
AUROC (CI)
Assessment
Lee et al[31]87CLDp-SWE≥ F20.872 (0.777-0.937)Good
F40.886 (0.794-0.947)Good
Fang et al[25]121CLDp-SWE≥ F20.855 (0.778-0.932)Good
≥ F30.890 (0.826-0.954)Good
Saadi et al[41]216CLDp-SWEF0-F10.744 (0.67-0.82)Acceptable
F30.82 (0.74-0.89)Good
F40.95 (0.91-0.98)Acceptable
Atzori et al[22]160CLDp-SWE - Philips ElastPQF0/10.828 (0.762-0.895)Good
F3/40.812 (0.734-0.889)Good
F40.856 (0.753-0.938)Good
Atzori et al[22]160CLDp-SWE - Siemens VTQF0/10.741 (0.659-0.823)Acceptable
F3/40.782 (0.702-0.861)Acceptable
F40.826 (0.734-0.918)Good
Roccarina et al[40]671NAFLDp-SWE by ElastPQF > 10.835 (0.72-0.93)Good
F > 20.831 (0.78-0.90)Good
F > 30.864 (0.82-0.93)Good
F = 40.952 (0.92-0.99)Excellent
Garcovich et al[26]253CLDX + p-SWEF ≥ 20.96 (0.93-0.99)Excellent
F ≥ 30.98 (0.97-1.00)Excellent
F40.99 (0.98-1.00)Excellent