Systematic Reviews
Copyright ©The Author(s) 2025.
World J Hepatol. Feb 27, 2025; 17(2): 100033
Published online Feb 27, 2025. doi: 10.4254/wjh.v17.i2.100033
Table 3 2D-shear wave elastography diagnostic efficacy (area under the receiver operating characteristic curves for fibrosis detection)
Ref.
Number of patients
Disease/diagnose
Diagnostic method
Fibrosis stage
AUROC (CI)
Assessment
Yoo et al[52]203CLD2D-SWE LOGIQ E9F20.910 (0.871-0.944)Excellent
F30.897 (0.844-0.939)Good
F40.931 (0.874-0.969)Excellent
2D-SWE LOGIQ S8F20.908 (0.874-0.940)Excellent
F30.905 (0.864-0.954)Excellent
F40.931 (0.889-0.964)Excellent
Kavak et al[29]253CHB2D-SWE-MPGF > 20.956 (0.920-0.991)Excellent
F > 30.978 (0.945-1.000)Excellent
Garcovich et al[26]253CLD2D-SWE-SSIF ≥ 20.96 (0.93-0.99)Excellent
F ≥ 30.98 (0.97-1.00)Excellent
F40.99 (0.98-1.00)Excellent
Cassinotto et al[23]577NAFLD2D-SWE-SSIF ≥ 20.84 (0.81-0.88)Exclusion
F ≥ 30.88 (0.84-0.91)Excellent
F40.86 (0.82-0.90)Excellent