Table 10 Diagnostic efficacy of sound touch elastography and related techniques (area under the receiver operating characteristic curves for fibrosis detection)
Ref. | Number of patients | Disease/diagnose | Diagnostic method | Fibrosis stage | AUROC (CI) | Assessment |
Gatos et al[27] | 152 | CLD | ViTE | F ≥ F1 | 0.9481 | Excellent |
F ≥ F2 | 0.9698 | Excellent | ||||
F ≥ F3 | 0.9846 | Excellent | ||||
F = F4 | 0.9524 | Excellent | ||||
Yang et al[50] | 106 | CLD | ViTE | F0 vs F1-3 | 0.88 | Good |
F0-1 vs F2-4 | 0.84 | Good | ||||
F0-2 vs F3-4 | 0.80 | Acceptable | ||||
F0-3 vs F4 | 0.80 | Acceptable | ||||
Yu et al[62] | 85 | T2DM | FibroTouch | ≥ F2 | 0.76 (0.66-0.86) | Acceptable |
≥ F3 | 0.81 (0.71-0.91) | Good | ||||
≥ F4 | 0.92 (0.85-1.00 | Excellent | ||||
Qu et al[60] | 237 | NAFLD | FibroTouch | ≥ F2 | 0.71 | Acceptable |
≥ F3 | 0.71 | Acceptable | ||||
F4 | 0.77 | Acceptable |