Copyright
©The Author(s) 2020.
World J Stem Cells. May 26, 2020; 12(5): 381-405
Published online May 26, 2020. doi: 10.4252/wjsc.v12.i5.381
Published online May 26, 2020. doi: 10.4252/wjsc.v12.i5.381
Ref. | Equipment system | Analysis software | MF (Tesla) | Sequence | Weighted images (TR/TE; ms) | FOV; MT; ST (mm) | Homing evaluation time |
Lim et al[33] | PC - Agilent Technologies | ImageJ (NIH) | 9.4 | T2 | T2: 4000/32.5 | NA; NA; 1.0 | 1, 3, 7, 10, 14 d |
Wang et al[29] | PC - PharmaScan - Bruker | ImageJ (NIH) | 7.0 | TSE FLASH GRE | T2: 3000/NA | 20 × 20; 256 × 256; 1.0 | 1, 3, 7 d |
ParaVision (Bruker) | T2*: 159.4/5 | 55 × 55; 256 × 256; 1.0 | |||||
Yun et al[30] | Philips Medical Systems; an animal coil | NA | 3.0 | FSE | T2: 4000/80 | 50; 256 × 256; 0.5 | 1 d, 3 w |
Argibay et al[38] | PC - Bio Spec - Bruker; surface coil array | ImageJ (NIH) | 9.4 | MGE | T2*: 2.9/1.5 | 19.2 × 19.2; 192 × 192; 1.0 | 4 h |
Duan et al[37] | Achieva - Philips Medical Systems; 4-channel rat coil | ImageJ (NIH) | 3.0 | FSE | T2: 800/60 | 60; 256 × 256; 1.0 | 1-4, 6-8 wk |
FFE | T2*: 500/18 | ||||||
Lu et al[35] | Achieva - Philips Medical Systems; 4-channel rat coil | NA | 3.0 | FSE | T2: 200/31 | 60 × 60; 267 × 268; 1.0 | 1, 3, 7, 14 d |
FFE | T2*: 500/18 | ||||||
Zhang et al[34] | Achieva - Philips Medical Systems | ImageJ (NIH) | 3.0 | FSE | T2: 800/60 | 60 × 60; 256 × 256; 1.0 | 1-6 wk |
PDW | PDW: 3000/20 | ||||||
FFE | T2*: 500/18 | ||||||
Lin et al[36] | Intera - Philips Medical Systems | ImageJ (NIH) | 3.0 | Multi SE | T2: 2000/20-80 | 80 × 80; 160 × 266; 2.0 | 1-6 wk |
Zhang et al[39] | PC - PharmaScan - Bruker | ImageJ (NIH) | 7.0 | Turbo RARE | T2: 6000/ 60 | 30; 256 × 256; 0.5 | 2 d, 8 d |
FLASH GRE | T2*: 400/3.5 | ||||||
Duan et al[40] | Achieva - Philips Medical Systems | ImageJ (NIH) | 3.0 | FSE | T2: 800/60 | 60; 256 × 256; 1.0 | 1, 2, 3, 4, 6 wk |
PDW | PDW: 3000/20 | ||||||
FFE | T2*: 500/18 | ||||||
Bai et al[42] | PC - PharmaScan - Bruker | ImageJ (NIH) | 7.0 | SE | T1: 500/15 | 20 × 20; 256 × 256; 1.0 | 1, 3, 5, 7, 10, 14 d |
FSE | T2: 2000/50 | ||||||
Chen et al[28] | PC - Bio Spec - Bruker | ImageJ (NIH) | 7.0 | RARE SE | T2: 3000/50 | 25.6; 256 × 256; 0.7 | 3 d, 7 d, 14 d |
Tan et al[41] | PC - Unity INOVA, Varian | NR | 7.0 | SE | T2: 2500/60 | 30 × 30; 512 × 512; NR | 1-42 d |
Janowski et al[44] | Sonata Maestro Class - Siemens; 8-channel head coil | Osirix (Pixmeo) Amira (Visage Imaging) | 1.5 | SWI | T2*: 49/40 | 230; 168 × 256; 1.6 | 1 d, 1 wk, 1 mo, 2 mo, 4 mo |
Park et al[43] | Achieva - Philips Medical Systems; animal coil | NA | 3.0 | SE | T2: 11000/125 | NA; 284 × 286; 0.7 | 0 h, 2 d |
Zhang et al[45] | Sigma - GE Healthcare; a human head coil | NA | 3.0 | FSE | T2: 5840/104 | 45 × 45; 256 × 256; 1.5-2.0 | 1 d, 3 d |
Map MSME SE | T2: 3500/20-160 | ||||||
Tarulli et al[46] | Sigma - GE Healthcare | NA | 3.0 | FSE | T2: 4500/35-75 | 40 × 40 × 17; 256 × 256; 1.0 | 1 d, 7 d, 14 d |
3D-SPGR | T2*: 25/7 | 40 × 40 × 20; 256 × 256; 1.0 | |||||
Liu et al[47] | Sigma - GE Healthcare; a rat coil | 3.0 | T2* | T2*: 2560/6.8 | 6.0; NR; 1.6 | 1, 7, 21 d | |
Wang et al[48] | Sigma - GE Healthcare | NA | 3.0 | FSE | T2: 5840/104 | 45 × 45; 256 × 256; 1.5 | 1, 7, 30 d |
Lee et al[50] | Sigma - GE Healthcare; a clinical coil | NA | 1.5 | TSE | T2: 2000/81 | 90; 192 × 192; 1.5 | 0, 1, 5, 12 d |
GRE | 280/20 | 20; 160 × 160; 1.5 | |||||
Song et al[49] | Sigma - GE Healthcare | NA | 1.5 | T2 | T2: 3500/80 | 60 × 60; 256 × 160; 2.0 | 1d, 3d, 1-4 wk |
3D GRE | T2*: 50/20 | 80 × 80; 256 × 160; 2.0 | |||||
Kim et al[51] | PC - Bio Spec - Bruker | NA | 4.7 | SE | T1: 600/14 | 40 × 30; 256 × 192; 1.0 | 2 d, 1 w, 2 w...10 wk |
RARE | T2: 5000/90 | ||||||
FLASH | T2*: 758 × 30 | ||||||
Guzman et al[52] | PC - Varian Medical Systems | NA | 4.7 | SE | T2: 2500/45 | 40; 256 × 256; 1.0 | 2 d, 7 d, 35 d |
3D GRE | T2*: 600/5 | 30 × 30 × 30; 128× 128 × 128 | |||||
Syková et al[53] | PC - Bio Spec-Bruker | NA | 4.7 | FGE | T2: NA | NA | 1 d, 1-7 wk |
Zhu et al[54] | Sigma - GE Healthcare | NA | 3.0 | SE | T2: 200/20 | NA | 1 d, 7 d |
- Citation: Nucci MP, Filgueiras IS, Ferreira JM, de Oliveira FA, Nucci LP, Mamani JB, Rego GNA, Gamarra LF. Stem cell homing, tracking and therapeutic efficiency evaluation for stroke treatment using nanoparticles: A systematic review. World J Stem Cells 2020; 12(5): 381-405
- URL: https://www.wjgnet.com/1948-0210/full/v12/i5/381.htm
- DOI: https://dx.doi.org/10.4252/wjsc.v12.i5.381