Table 6 Definition of liver stiffness measurement by transient elastography cut-off values for advanced Fontan-associated liver disease
LSM cut-off value | Sensitivity | Specificity | PPV | NPV | Accuracy | |
Rule-out cut-off | < 20 | 0.957 | 0.474 | 0.815 | 0.818 | 0.815 |
Optimal cut-off | 25 | 0.696 | 0.684 | 0.842 | 0.481 | 0.691 |
Rule-in cut-off | ≥ 40 | 0.196 | 0.947 | 0.900 | 0.327 | 0.415 |
- Citation: Cuadros M, Abadía M, Castillo P, Martín-Arranz MD, Gonzalo N, Romero M, García-Sánchez A, García-Samaniego J, Olveira A, Ruiz-Cantador J, González-Fernández Ó, Ponz I, Merás P, Merino C, Rodríguez-Chaverri A, Balbacid E, Froilán C. Role of transient elastography in the diagnosis and prognosis of Fontan-associated liver disease. World J Gastroenterol 2025; 31(11): 103178
- URL: https://www.wjgnet.com/1007-9327/full/v31/i11/103178.htm
- DOI: https://dx.doi.org/10.3748/wjg.v31.i11.103178