Observational Study
Copyright ©The Author(s) 2025.
World J Gastroenterol. Mar 21, 2025; 31(11): 103178
Published online Mar 21, 2025. doi: 10.3748/wjg.v31.i11.103178
Table 5 Definition of liver stiffness measurement by transient elastography cut-off values for Fontan-associated liver disease

LSM cut-off value
Sensitivity
Specificity
PPV
NPV
Accuracy
Rule-out cut-off< 150.9690.5000.9260.7140.907
Optimal cut-off200.9230.8000.9680.6150.907
Rule-in cut-off≥ 250.6151.0001.0000.2860.667

  • Citation: Cuadros M, Abadía M, Castillo P, Martín-Arranz MD, Gonzalo N, Romero M, García-Sánchez A, García-Samaniego J, Olveira A, Ruiz-Cantador J, González-Fernández Ó, Ponz I, Merás P, Merino C, Rodríguez-Chaverri A, Balbacid E, Froilán C. Role of transient elastography in the diagnosis and prognosis of Fontan-associated liver disease. World J Gastroenterol 2025; 31(11): 103178
  • URL: https://www.wjgnet.com/1007-9327/full/v31/i11/103178.htm
  • DOI: https://dx.doi.org/10.3748/wjg.v31.i11.103178