Copyright
©The Author(s) 2024.
World J Gastroenterol. May 7, 2024; 30(17): 2311-2320
Published online May 7, 2024. doi: 10.3748/wjg.v30.i17.2311
Published online May 7, 2024. doi: 10.3748/wjg.v30.i17.2311
Ref. | Study design | No. of pts CH-EUS/ EUS | Needle size (G), type | Contrast agent | Sensitivity (%), CH-EUS-FNA/B vs no CH-EUS-FNA/B | P value | Other findings |
Hou et al[71], 2015 | R | 58/105 | 22, FNA | Sonovue | 81.6 vs 70.8 | NS | |
Sugimoto et al[24], 2015 | RCT | 20/20 | 22, 25, FNA | Sonazoid | 90.0 vs 85.0 | NS | Adequate for the 1st pass only |
Seicean et al[12], 2017 | P | 51 | 22, FNA | Sonovue | 82.9 vs 73.2 | NS | |
Facciorusso et al[72], 2020 | R | 103/103 | 22, FNA | Sonovue | 87.6 vs 80.0 | NS | |
Seicean et al[29], 2020 | RCT | 148 | 22, FBA | Sonovue | 87.6 vs 85.5 | NS | |
Cho et al[26], 2021 | RCT | 120/120 | 19-25, FNA, FNB | Sonovue | 85.8 vs 88.3 | NS | Procore in 80% |
Itonaga et al[30], 2020 | P | 93 | 22, FNA | Sonazoid | 84.9 vs 68.8 | 0.003 | Better adequacy in homogenous lesions and heterogenous lesions with non-enhancement areas |
Lai et al[32], 2022 | R | 48/85 | 22, FNB | Sonazoid | 91.0 vs 90.0 | NS | 2.2 vs 3.6 passes |
Kuo et al[23], 2023 | RCT | 59/59 | 22, FNB | Sonazoid | 100.0 vs 100.0 | NS | A nodule < 4 cm and a sample length > 1 cm improved the rate of diagnosis |
- Citation: Gheorghiu MI, Seicean A, Pojoga C, Hagiu C, Seicean R, Sparchez Z. Contrast-enhanced guided endoscopic ultrasound procedures. World J Gastroenterol 2024; 30(17): 2311-2320