Copyright
©The Author(s) 2020.
World J Gastroenterol. Nov 14, 2020; 26(42): 6669-6678
Published online Nov 14, 2020. doi: 10.3748/wjg.v26.i42.6669
Published online Nov 14, 2020. doi: 10.3748/wjg.v26.i42.6669
Table 4 Univariate analysis influencing factors for dose of sedation
Factors | Univariate analysis | |||
P value | Odds ratio | 95%CI | ||
Lower limit | Upper limit | |||
Age (less than 65 yr) | 0.241 | 0.500 | 0.157 | 1.594 |
Gender | 0.556 | 0.708 | 0.224 | 2.240 |
Correct visual selection | 0.700 | 1.286 | 0.358 | 4.617 |
Correct CDE | 0.770 | 0.655 | 0.039 | 11.119 |
Intervention | 0.466 | 0.643 | 0.196 | 2.108 |
Insertion time (more than 22 min.) | 0.895 | 0.917 | 0.251 | 3.350 |
Total examination time (more than 80 min.) | 0.797 | 1.179 | 0.377 | 4.125 |
CRP level normal | 0.805 | 1.167 | 0.344 | 3.956 |
Serum amylase level normal | 0.432 | 0.583 | 0.152 | 2.240 |
Billroth II and PD | 0.721 | 0.808 | 0.250 | 2.612 |
Previous surgery more than 2 times | 0.270 | 0.467 | 0.120 | 1.810 |
- Citation: Niwa Y, Nakamura M, Kawashima H, Yamamura T, Maeda K, Sawada T, Mizutani Y, Ishikawa E, Ishikawa T, Kakushima N, Furukawa K, Ohno E, Honda T, Ishigami M, Fujishiro M. Accuracy of carbon dioxide insufflation for endoscopic retrograde cholangiopancreatography using double-balloon endoscopy. World J Gastroenterol 2020; 26(42): 6669-6678
- URL: https://www.wjgnet.com/1007-9327/full/v26/i42/6669.htm
- DOI: https://dx.doi.org/10.3748/wjg.v26.i42.6669