Meta-Analysis
Copyright ©The Author(s) 2018.
World J Gastroenterol. Mar 14, 2018; 24(10): 1167-1180
Published online Mar 14, 2018. doi: 10.3748/wjg.v24.i10.1167
Table 3 Accuracy of the different technologies
Analysis groupsNo. of studiesPooled estimates (95%CI)Likelihood ratios (95%CI)Diagnostic odds ratio (95%CI)Area under SROC curve (95%CI)
SensitivitySpecificityLHR+LHR-DOR

All
VCE50.86 (0.62-0.95)0.87 (0.72-0.95)6.7 (2.6-17.8)0.17 (0.05-0.53)41 (6-297)0.93 (0.90-0.95)
DBC60.67 (0.44-0.84)0.86 (0.72-0.94)4.9 (2.1-11.3)0.38 (0.20-0.73)13 (3-48)0.84 (0.81-0.87)
Magnification50.90 (0.77-0.96)0.87 (0.81-0.91)7.0 (4.6-10.7)0.11 (0.05-0.28)62 (18-209)0.93 (0.91-0.95)
CLE90.87 (0.71-0.95)0.94 (0.87-0.97)14.0 (6.1-32.4)0.14 (0.06-0.33)101 (23-442)0.96 (0.94-0.97)
Real-time
Kudo PP100.78 (0.57-0.91)0.89 (0.80-0.94)6.9 (3.5-13.5)0.24 (0.11-0.55)28 (7-110)0.91 (0.89-0.94)
CLE60.91 (0.66-0.98)0.97 (0.94-0.98)28.4 (13.6-59.1)0.09 (0.02-0.43)322 (41-2529)0.98 (0.97-0.99)
All Kudo PP120.78 (0.61-0.88)0.86 (0.76-0.92)5.5 (2.9-10.1)0.26 (0.14-0.50)21 (7-66)0.89 (0.86-0.92)