Table 6 Comparison of the clinical success rates for the combined parameters in each indication
Clinical success rate | ||||||
Indications | Refractory bleeding (n = 18) | Leak (n = 27) | Fistula (n = 11) | |||
Combined parameters | SS (n = 7) | TG (n = 11) | SS (n = 2) | TG (n = 25) | SS (n = 5) | TG (n = 6) |
D ≤ 10, Immediate | 100% | 100% | - | 100% | - | - |
D ≤ 10, Acute | 100% | - | 50% | 100% | - | - |
D ≤ 10, Chronic | 66.7% | 100% | - | - | 80% | 100% |
10 < D ≤ 20, Immediate | - | 100% | - | 66.7% | - | - |
10 < D ≤ 20, Acute | - | 100% | - | 100% | - | - |
10 < D ≤ 20, Chronic | - | 100% | - | - | - | 100% |
D > 20, Immediate | - | 100% | - | 100% | - | - |
D > 20, Acute | - | - | - | 75% | - | - |
D > 20, Chronic | - | 33.3% | - | - | - | 50% |
- Citation: Kobara H, Mori H, Fujihara S, Nishiyama N, Chiyo T, Yamada T, Fujiwara M, Okano K, Suzuki Y, Murota M, Ikeda Y, Oryu M, AboEllail M, Masaki T. Outcomes of gastrointestinal defect closure with an over-the-scope clip system in a multicenter experience: An analysis of a successful suction method. World J Gastroenterol 2017; 23(9): 1645-1656
- URL: https://www.wjgnet.com/1007-9327/full/v23/i9/1645.htm
- DOI: https://dx.doi.org/10.3748/wjg.v23.i9.1645