Outcomes | Total patients (n = 58) |
Technical success rate, % (95%CI) | 89.7 (81.0-98.4) |
Clinical success rate, % (95%CI) | 84.5 (74.3-94.7) |
Complications, n (%) | 1 (1.8) in 56 cases used |
The procedure time, median (range), min | 8 (1-36) in 52 successful cases |
- Citation: Kobara H, Mori H, Fujihara S, Nishiyama N, Chiyo T, Yamada T, Fujiwara M, Okano K, Suzuki Y, Murota M, Ikeda Y, Oryu M, AboEllail M, Masaki T. Outcomes of gastrointestinal defect closure with an over-the-scope clip system in a multicenter experience: An analysis of a successful suction method. World J Gastroenterol 2017; 23(9): 1645-1656
- URL: https://www.wjgnet.com/1007-9327/full/v23/i9/1645.htm
- DOI: https://dx.doi.org/10.3748/wjg.v23.i9.1645