Table 4 Various studies of the diagnostic performance of transient elastography for clinically significant portal hypertension
Ref.PlaceYearNumber of patientsCorrelation coefficient (r) or r2 of TE with HVPGAUROC (95%CI)Best cut-off of TE for CSPH
Carrión et al[33]Spain20061240.8400.94-
Vizzutti et al[14]Italy2007610.8100.99 (0.92-0.99)13.6 (PPV 97%)
Lemoine et al[34]France2008920.5300.84 (0.80-0.88)34.9 for alcohol (PPV 98%)
20.5 for HCV (PPV 88%)
Bureau et al[35]France20081500.8580.945 (0.904-0.987)21 (PPV 92%)
Sánchez-Conde et al[36]Spain2011380.4600.80 (0.64-0.97)14 (PPV 84%)
Reiberger et al[13]Austria20125020.7940.817 (0.752-0.891)18 (PPV 86%)
Llop et al[20]Spain2012970.5520.840 (0.748-0.933)21 (PPV 81%)
Berzigotti et al[37]Spain2013117-0.883 (0.824-0.943)21.1 (sensitivity 65%)
Hong et al[38]South Korea2013590.4960.85121.95 (PPV 87%)
Salzl et al[28]Austria2014880.7650.8716.8 (sensitivity 90%)
Augustin et al[39]Spain201440--25
Zykus et al[31]Lithuania20151070.7500.94917.4 (accuracy 89%)
Procopet et al[32]Europe2015202-0.94 (0.89-0.99)21.1 (accuracy 90%)
(Multicentric)
Kitson et al[40]Australia2015950.3800.90 (0.83-0.97)29.0 (PPV 100%)
Elkrief et al[25]France201579-0.78 (0.58-0.98)65.3 (PPV 100%)
Schwabl et al[41]Austria20152260.836 and 0.8460.957 & 0.96216.1 (accuracy 89% & 90%)
Hametner et al[29]Austria2016236-0.92 (0.86-0.96)24.8 (PPV 98%)
This studyIndia20163260.3610.740 (0.662-0.818)21.6 (PPV 93%)
Total2515Weighted mean: 21.8