Retrospective Study
Copyright ©The Author(s) 2017.
World J Gastroenterol. Jan 28, 2017; 23(4): 687-696
Published online Jan 28, 2017. doi: 10.3748/wjg.v23.i4.687
Table 3 Predictive values of transient elastography for the prediction of clinically significant portal hypertension (HVPG ≥ 10 mmHg)
TE cut-off value (mmHg)CSPH (n)No CSPH (n)Total (n)Sensitivity (95%CI)Specificity (95%CI)PPV (95%CI)NPV (95%CI)Accuracy (95%CI)LR+ (95%CI)LR-(95%CI)
≥ 21.62191623579% (74%-83%)67% (52%-80%)93% (89%-96%)35% (25%-46%)77% (72%-82%)2.4 (1.6-3.5)0.3 (0.2-0.4)
< 21.6593291
Total27848326