Table 4 Comparison of video capsule endoscopy and multiphase computed tomography enterography in all patients with capsule endoscopy and computed tomography enterography performed within 1 year of double balloon enteroscopy
Comparison testStatisticCount summary%95%CI
Lower limit (%)Upper limit (%)
VCETotal, n337
Sensitivity171/23373.467.779.1
Specificity30/10428.820.137.6
DX yield245/33772.767.977.5
Accuracy201/33759.654.464.9
MPCTETotal, n252
Sensitivity55/15735.027.642.5
Specificity68/9571.662.580.6
DX yield82/25232.526.838.3
Accuracy123/25248.842.655.0