Copyright
©The Author(s) 2017.
World J Gastroenterol. Jun 7, 2017; 23(21): 3784-3796
Published online Jun 7, 2017. doi: 10.3748/wjg.v23.i21.3784
Published online Jun 7, 2017. doi: 10.3748/wjg.v23.i21.3784
Metric | Definition | Suggested target (references) |
Cecal intubation rate | The frequency of completed colonoscopies (cecum is visualized) | Overall: ≥ 90% |
Screening: ≥ 95%[19] | ||
Polyp detection rate | The proportion of patients with at least one polyp | N/A |
Adenoma detection rate | The proportion of patients with at least one adenoma | Men: ≥ 30% |
Women: ≥ 20%[19] | ||
Adenoma per colonoscopy | The mean number of adenomas detected per colonoscopy | N/A |
Polyp miss rate (PMR) | The proportion of polyps missed during a first pass and detected by a second one. It is used in back-to-back studies. | N/A |
Adenoma miss rate | The proportion of adenomas missed during a first pass and detected by a second one. It is used in back-to-back studies. | N/A |
- Citation: Gkolfakis P, Tziatzios G, Dimitriadis GD, Triantafyllou K. New endoscopes and add-on devices to improve colonoscopy performance. World J Gastroenterol 2017; 23(21): 3784-3796
- URL: https://www.wjgnet.com/1007-9327/full/v23/i21/3784.htm
- DOI: https://dx.doi.org/10.3748/wjg.v23.i21.3784