Randomized Clinical Trial
Copyright ©The Author(s) 2016.
World J Gastroenterol. Oct 21, 2016; 22(39): 8820-8830
Published online Oct 21, 2016. doi: 10.3748/wjg.v22.i39.8820
Table 3 Technical characteristics and outcomes of endoscopic ultrasound-guided fine needle aspiration with the 2 needles in all patients (n = 56) and in patients with an available histological specimen (n = 36)
CharacteristicType of needle (all cases/histology cases)
AN (n = 56/36)PC (n = 56/36)P value
Needle passes, mean (SD)1.5 (0.6)/1.5 (0.7)1.7 (0.6)/1.7 (0.6)0.14/0.16
Cellularity, mean (SD)1.7 (0.6)/1.7 (0.6)1.1 (0.3)/1 (0)0.058/0.0342
Cytologic/histologic quality, median (range)2.6 (0-3)/ 3 (0-3)2.4 (0-3)/3 (0-3)0.083/0.49
Adequacy for diagnosis, n (%)54 (96.4)/35 (97.2)51 (91.1)/36 (100)0.38/0.99
Correct diagnosis1, n (%)48/54 (88.9)/30/35 (85.7)49/51 (96.1)/34/36 (94.4)0.25/0.25