Copyright
©The Author(s) 2016.
World J Gastroenterol. Mar 28, 2016; 22(12): 3355-3362
Published online Mar 28, 2016. doi: 10.3748/wjg.v22.i12.3355
Published online Mar 28, 2016. doi: 10.3748/wjg.v22.i12.3355
Actual polyp size, mm | Mean measurementerror ± SD, mm | Pooled standardizedpolyp size ± SD, % |
≤ 5 (n = 9) | 1.9 ± 0.8 | 142.5 ± 18.7 |
6-9 (n = 14) | 0.9 ± 1.2 | 111.2 ± 16.7 |
≥ 10 (n = 6) | 1.0 ± 1.4 | 109.2 ± 12.2 |
≥ 6 (n = 20) | 0.9 ± 1.3 | 110.5 ± 14.6 |
- Citation: Liu JY, Chen LD, Cai HS, Liang JY, Xu M, Huang Y, Li W, Feng ST, Xie XY, Lu MD, Wang W. Ultrasound virtual endoscopy: Polyp detection and reliability of measurement in an in vitro study with pig intestine specimens. World J Gastroenterol 2016; 22(12): 3355-3362
- URL: https://www.wjgnet.com/1007-9327/full/v22/i12/3355.htm
- DOI: https://dx.doi.org/10.3748/wjg.v22.i12.3355