Basic Study
Copyright ©The Author(s) 2015.
World J Gastroenterol. Aug 28, 2015; 21(32): 9544-9553
Published online Aug 28, 2015. doi: 10.3748/wjg.v21.i32.9544
Table 2 Changes of portal vein in experimental group 3 before and after perfusion
Portal venous diameter (mm)Pressure (kPa)Extrahepatic portal venous bypassIntrahepatic portal venous bypass
Before perfusion (n = 5)
19.51.2--
110.31.6--
111.51.4--
19.81.3--
112.41.5--
mean ± SD10.70 ± 1.221.40 ± 0.16
Immediately after perfusion (n = 5)
119.43.1--
118.63.3--
121.13.5--
117.92.8--
119.72.9--
mean ± SD19.34 ± 1.213.12 ± 0.29
2 wk after perfusion (n = 4)
114.22.4-+
115.42.6-+
116.32.8--
116.62.6-+
mean ± SD15.80 ± 3.662.60 ± 0.16
4 wk after perfusion (n = 3)
111.42.2-+
116.51.8-+
117.92.1-+
mean ± SD15.63 ± 1.082.03 ± 0.21
6 wk after perfusion (n = 3)
111.62.1-+
118.31.7-+
117.51.9-+
mean ± SD15.27 ± 3.361.90 ± 0.20