Stent failure | P value | ||
Yes (n = 40) | No (n = 16) | ||
Age (yr) | 67 ± 13.2 | 73.9 ± 12.1 | 0.72 |
Sex | 0.43 | ||
Men | 27 (67.5) | 9 (56.2) | |
Women | 13 (32.5) | 7 (43.8) | |
Procedure time (min) | 36.4 ± 19.9 | 31.5 ± 18.6 | 0.39 |
Chemotherapy | 29 (72.5) | 8 (50) | 0.10 |
Response | 13 (32.5) | 1 (6.3) | 0.09 |
CEA (ng/mL) | 31.1 ± 111.5 | 5.1 ± 5.9 | 0.39 |
Type of stent | 0.31 | ||
Covered | 21 (52.5) | 6 (37.5) | |
Uncovered | 19 (47.5) | 10 (62.5) | |
Carcinoma peritonei | 14 (35.0) | 6 (37.5) | 0.86 |
Cancer stage1 | 0.47 | ||
III | 4 (10) | 1 (6.2) | |
IV | 36 (90) | 15 (93.6) | |
Gastric cancer | |||
Chemotherapy | 19 (73.1) | 3 (33.3) | 0.03 |
Covered stent | 16 (61.5) | 5 (55.6) | 0.75 |
CEA (ng/mL) | 44.6 ± 138.3 | 5.7 ± 6.9 | 0.44 |
Pancreatic cancer, | |||
Chemotherapy | 10 (71.4) | 5 (71.4) | 1.00 |
Covered stent | 5 (35.7) | 1 (14.3) | 0.30 |
CEA (ng/mL) | 7.0 ± 7.1 | 4.4 ± 4.9 | 0.42 |
CA 19-9 (IU/mL) | 24.597 ± 73.120 | 1.731 ± 2.484 | 0.46 |
Location of obstruction | 0.57 | ||
Gastric body | 4 (10) | 1 (6.2) | |
Pylorus | 22 (55) | 7 (43.8) | |
Duodenum | 14 (35) | 8 (50) |