Case Report
Copyright ©The Author(s) 2015.
World J Gastroenterol. Jun 28, 2015; 21(24): 7589-7593
Published online Jun 28, 2015. doi: 10.3748/wjg.v21.i24.7589
Table 1 Summary of published cases of enteral metallic stent placement by balloon enteroscopy and its overtube
Ref.Age (yr)SexDiseasePast surgeryEndoscopeStentImproveComplicationSurvival
Ross et al[1], 200659MLymphadenopathyof lung cancerNoDBE (EN450T5)UltraflexYesNoNA
Hayashi et al[2], 200665FJejunal cancerNoDBE (EN450P5)UltraflexYesNoNA
73MPancreatic cancerNoSBE (SIFQ180)WallflexYesNoNA
Espinel et al[3], 201168MPancreatic cancerPPPDDBE (EN450T5)Niti-SYesNoNA
81MPancreatic cancerNoDBE (EC450BI5)WallflexYesNoNA
Kida et al[4], 201380FPancreatic cancerWhippleDBENAYesNo3 mo
48MPancreatic cancerPPPDSBE (SIFQ260)Niti-SYesNo4 mo
Popa et al[5], 201476MMiddle cholangiocarcinomaPPPDSBE (SIFQ260)Niti-SYesCholangitis14 mo
Our cases51FHilar cholangiocarcinoma, Gastric cancerLL + RY, DG + RYSBE (SIFQ260)Niti-SYesNo1 mo