EZ-FIX(n = 53) | Non-EZ-FIX(n = 52) | P value | |
Below 90% in SaO2 for ≥ 30 s | 4 (3.8) | 6 (5.7) | 0.060 |
↓ 20 mmHg in BP | 8 (7.6) | 9 (8.6) | 0.800 |
↓ 20% in PR | 3 (2.9) | 3 (2.9) | 1 |
Death | - | - | - |
Procedure-related complications | 0.735 | ||
Pancreatitis | 5 | 4 | |
Bleeding | 1 | 2 | |
Perforation | - | 1 |
- Citation: Lee S, Han JH, Lee HS, Kim KB, Lee IK, Cha EJ, Shin YD, Park N, Park SM. Efficacy and safety of a patient-positioning device (EZ-FIX) for endoscopic retrograde cholangiopancreatography. World J Gastroenterol 2015; 21(19): 5995-6000
- URL: https://www.wjgnet.com/1007-9327/full/v21/i19/5995.htm
- DOI: https://dx.doi.org/10.3748/wjg.v21.i19.5995