Table 2 Accuracy of endoscopic ultrasound for staging T1a or T1b esophageal squamous cell carcinoma
Pathology | Expert 1 | Expert 2 | Common results | ||
T1a (n = 36) | T1b (n = 36) | T1a (n = 39) | T1b (n = 33) | T1a (n = 36) | |
T1a (n = 35) | 23 | 13 | 25 | 10 | 26 |
T1b (n = 37) | 13 | 24 | 14 | 23 | 10 |
Group | |||||
AC | 65.30% | 66.70% | 70.80% | ||
SE | 65.70% | 64.10% | 74.30% | ||
FPR | 35.10% | 35.90% | 27.00% | ||
FNR | 34.30% | 30.30% | 25.70% | ||
SP | 64.90% | 69.70% | 73.00% | ||
PPV | 63.90% | 71.40% | 72.20% | ||
NPV | 66.70% | 62.20% | 75.00% | ||
AUC | 0.653 | 0.668 | 0.736 | ||
P value | 0.026 | 0.014 | 0.001 |