Ref. | Pts | Adequatecleansing | Excretionrate | Polyp≥6 mm | Polyp≥10 mm | ||
Sensitivity(95%CI) | Specificity(95%CI) | Sensitivity(95%CI) | Specificity(95%CI) | ||||
Eliakim et al[9] | 104 | 78% | 81%1 | 89% | 76% | 88% | 89% |
(68%-86%) | (70%-97%) | (72%-78%) | (56%-98%) | (86%-90%) | |||
Spada et al[12] | 117 | 85% | 81%1 | 84% | 64% | 88% | 95% |
(73%-88%) | (74%-95%) | (52%-76%) | (76%-99%) | (90%-100%) | |||
Rex et al[19] | 884 | 80% | 91%2 | 88% | 82% | 92% | 95% |
(76%-83%) | (82%-93%) | (80%-83%) | (82%-97%) | (94%-95%) |