Copyright
©2014 Baishideng Publishing Group Inc.
World J Gastroenterol. Nov 28, 2014; 20(44): 16596-16602
Published online Nov 28, 2014. doi: 10.3748/wjg.v20.i44.16596
Published online Nov 28, 2014. doi: 10.3748/wjg.v20.i44.16596
Table 4 Diagnostic accuracy of colon capsule endoscopy for the detection of significant colon polyps (≥ 6 mm or ≥ 3 polyps)
Ref. | Year published | Colon capsule | Number of patients included | Sensitivity | Specificity | PPV | NPV |
Schoofs et al[3] | 2006 | CCE-1 | 36 | 77% | 70% | 59% | 84% |
Eliakim et al[37] | 2006 | CCE-1 | 84 | 50% | 83% | 40% | 88% |
Van Gossum et al[10] | 2009 | CCE-1 | 320 | 64% | 84% | - | - |
Gay et al[39] | 2010 | CCE-1 | 126 | 87.5% | 76% | 79% | 85% |
Pilz et al[38] | 2010 | CCE -1 | 56 | 79% | 54% | 63% | 71% |
Sacher-Huvelin et al[11] | 2010 | CCE-1 | 545 | 39% | 88% | 47% | 85% |
Eliakim et al[4] second gen | 2009 | CCE-2 | 98 | 89% | 76% | 46% | 97% |
Spada et al[8] | 2011 | CCE-2 | 109 | 84% | 64% | - | - |
Rex et al[6] | 2013 | CCE-2 | 689 | 81% | 93% | - | - |
- Citation: Tal AO, Vermehren J, Albert JG. Colon capsule endoscopy: Current status and future directions. World J Gastroenterol 2014; 20(44): 16596-16602
- URL: https://www.wjgnet.com/1007-9327/full/v20/i44/16596.htm
- DOI: https://dx.doi.org/10.3748/wjg.v20.i44.16596