Table 1 Performance of colon capsule endoscopy after incomplete colonoscopy
nPillCam Colon™ capsule generationSame day CCEColon preparation regimentPreparation adequacyCompletion of CCEComplementation of ICAdditional FindingsStudy design details
Spada et al[33], 20081First04 L of PEG + NaP boostersFair100%100%100%Case report
Triantafyllou et al[34], 200912First04 L of PEG + NaP boosters58%8%50%30%Retrospective
Case series
Fernández-Urién et al[35], 20111First0NRNR100%100%NoneCase report
Pioche et al[37], 2012107First01 or 2 L of PEG (MoviPrep®) + NaP boosters76%83.20%NR33.6%Prospective cohort study; results are not reported separately for the incomplete colonoscopy cases (n = 77)
Alarcón-Fernández et al[39], 201334First03 L of PEG + NaP boosters64.70%77%85.30%23.5%Prospective cohort study
Triantafyllou et al[40], 201475First33%1 L of PEG + NaP boosters or 4 L of PEG160%76%91%44%Prospective cohort study
Baltes et al[41], 201345Second0PEG (MoviPrep®) + PEG/NaP boosters70%80%87%18%Prospective cohort study (preliminary data)
Spada et al[42], 201350Second04 L of PEG83%NR98%14%Prospective cohort study (preliminary data); compares CCE-CTC
Nogales et al[43], 201396SecondNRNRNR72%93%58%Prospective cohort study
Negreanu et al[44], 20143Second04 L of PEG + PEG boostersNRNR100%100%Case series