Operator | Procedures | HD+ with i-Scan | Standard white light | Lesions | No. of lesions (mean number of lesions/procedure) | P value | |
HD+ with i-Scan | Standard white light | ||||||
1 | 264 | 57 | 207 | 330 | 117 (2.05) | 213 (1.02) | < 0.0001 |
2 | 300 | 72 | 228 | 375 | 132 (1.83) | 243 (1.07) | 0.089 |
3 | 276 | 60 | 216 | 294 | 114 (1.9) | 180 (0.83) | < 0.0001 |
4 | 261 | 63 | 198 | 267 | 96 (1.52) | 171 (0.86) | 0.71 |
Total | 1101 | 252 | 849 | 1266 | 459 (1.82) | 807 (0.95) | < 0.0001 |
- Citation: Testoni PA, Notaristefano C, Vailati C, Leo MD, Viale E. High-definition colonoscopy with i-Scan: Better diagnosis for small polyps and flat adenomas. World J Gastroenterol 2012; 18(37): 5231-5239