B coefficient | P value | OR | 95% CI | Pseudo R-squared | |
Gender (F) | -0.0371 | 0.845 | 0.96 | 0.66-1.39 | 0.0001 |
Age | 0.00759 | 0.152 | 1.01 | 0.99-1.02 | 0.0032 |
Hospitalized | 0.722 | 0.054 | 2.06 | 0.99-4.29 | 0.0055 |
Diabetes | 0.3 | 0.256 | 1.35 | 0.80-2.27 | 0.0019 |
Hemiplegia | 1.57 | 0.200 | 4.82 | 0.43-53.5 | 0.0027 |
Renal disease | 0.233 | 0.513 | 1.26 | 0.63-2.54 | 0.0007 |
DM with EOD | -0.048 | 0.936 | 0.95 | 0.29-3.09 | 0.00001 |
No bleed | Reference | 0.0167 | |||
Occult bleed | 0.517 | 0.095 | 1.68 | 0.91-3.07 | |
Overt bleed | 0.87 | 0.002 | 2.39 | 1.36-4.16 | |
Change in BM | 0.0148 | 0.952 | 1.01 | 0.62-1.65 | 0.00001 |
Bowel obstruction | 0.92 | 0.023 | 2.51 | 1.13-5.55 | 0.0078 |
Abdominal surgery | 0.439 | 0.023 | 1.55 | 1.06-2.26 | 0.0079 |
Abdominal radiation | 0.0228 | 0.974 | 1.02 | 0.26-4.00 | 0.00001 |
Opiate use | 0.479 | 0.094 | 1.61 | 0.92-2.82 | 0.0042 |
- Citation: Lee MM, Jacques A, Lam E, Kwok R, Lakzadeh P, Sandhar A, Segal B, Svarta S, Law J, Enns R. Factors associated with incomplete small bowel capsule endoscopy studies. World J Gastroenterol 2010; 16(42): 5329-5333
- URL: https://www.wjgnet.com/1007-9327/full/v16/i42/5329.htm
- DOI: https://dx.doi.org/10.3748/wjg.v16.i42.5329