Brief Article
Copyright ©2010 Baishideng Publishing Group Co.
World J Gastroenterol. Sep 21, 2010; 16(35): 4428-4435
Published online Sep 21, 2010. doi: 10.3748/wjg.v16.i35.4428
Table 2 Comparison of manometric parameter values during the treadmill stress test and during the 24-h monitoring period in patients with and without significant (> 50%) coronary artery narrowing
ParameterCAD- (n = 35)
CAD+ (n = 28)
24 hextP24 hextP
Contractions per minute1.5 ± 0.82.7 ± 1.70.0011.9 ± 1.52.7 ± 2.20.04
Peristaltic contractions (%)64.3 ± 9.647.2 ± 8.40.00167.7 ± 28.656.9 ± 18.70.03
Complete peristalsis (%)43.9 ± 15.335.6 ± 18.50.14051.9 ± 10.949.3 ± 26.50.70
Reduced peristalsis (%)18.3 ± 13.216.2 ± 14.80.63013.3 ± 6.310.1 ± 7.20.30
Interrupted peristalsis (%)37.8 ± 10.840.1 ± 30.00.69034.8 ± 8.536.8 ± 24.10.70
Simultaneous/mixed contractions (%)35.7 ± 9.649.3 ± 23.80.01032.3 ± 8.643.0 ± 18.70.02
Complete contractions (%)16.6 ± 5.235.6 ± 28.50.01014.9 ± 4.430.6 ± 30.10.03
Simultaneous contractions (%)83.4 ± 5.371.1 ± 28.70.04085.1 ± 4.969.4 ± 30.10.03