Table 2 Validity of rapid urease tests in the eradicated group
MethodSensitivity (%)Specificity (%)PPV (%)NPV (%)Accuracy (%)P1
Sampling over antrum with reaction time: 30 min
HelicotecUT plus50.0100.0100.087.789.0
HelicotecUT44.1100.0100.086.487.7
CLO55.9100.0100.089.090.3
ProntoDry50.0100.0100.087.789.00.913
Sampling over antrum with reaction time: 24 h
HelicotecUT plus61.8100.0100.090.391.6
HelicotecUT58.8100.0100.090.091.0
CLO64.799.295.791.091.6
ProntoDry64.7100.0100.091.092.30.983
Sampling over antrum plus body with reaction time: 30 min
HelicotecUT plus88.299.296.896.896.8
HelicotecUT82.4100.0100.095.396.1
CLO88.298.393.896.796.1
ProntoDry82.4100.0100.095.396.10.987