Copyright
©2009 The WJG Press and Baishideng.
World J Gastroenterol. May 21, 2009; 15(19): 2361-2366
Published online May 21, 2009. doi: 10.3748/wjg.15.2361
Published online May 21, 2009. doi: 10.3748/wjg.15.2361
Sensitivity | Specificity | PPV | NPV | Accuracy | |
EUS | |||||
Overall | 66.7 | 84.2 | 50.0 | 91.4 | 80.9 |
5-10 mm | 44.4 | 86.0 | 36.4 | 89.6 | 79.7 |
11-20 mm | 88.9 | 81.5 | 61.5 | 95.7 | 83.3 |
US | |||||
Overall | 47.4 | 72.0 | 30.0 | 84.4 | 67.0 |
5-10 mm | 20.0 | 83.3 | 20.0 | 83.3 | 72.4 |
11-20 mm | 77.8 | 51.9 | 35.0 | 87.5 | 63.9 |
- Citation: Cheon YK, Cho WY, Lee TH, Cho YD, Moon JH, Lee JS, Shim CS. Endoscopic ultrasonography does not differentiate neoplastic from non-neoplastic small gallbladder polyps. World J Gastroenterol 2009; 15(19): 2361-2366
- URL: https://www.wjgnet.com/1007-9327/full/v15/i19/2361.htm
- DOI: https://dx.doi.org/10.3748/wjg.15.2361