Table 1 Sensitivity, specificity and likelihood ratio of positive test (LR+) of C14-UBT and IgG and IgA antibodies against H pylori at cut-off values 300 and 500 in vagotomized (vag) or medically (med) treated peptic ulcer patients (med) and in community controls (con)
Sensitivity (95% CI)Specificity (95% CI)LR+ (95% CI)
vagmedconvagmedconvagmedcon
Method of detection
C14-UBT94 (85-99)92 (81-98)96 (87-100)85 (62-97)80 (56-94)90 (73-98)6.3 (2.4-31.5)4.6 (1.7-17.6)9.3 (3.0-46.6)
Serology IgG30095 (86-99)98 (90-100)93 (83-98)41 (21-64)50 (28-72)68 (49-83)1.6 (0.9-3.2)2.0 (1.0-4.2)2.9 (1.5-6.4)
Serology IgG50087 (76-94)90 (79-97)83 (70-91)55 (32-76)50 (28-72)71 (52-86)1.9 (1.0-4.2)1.8 (0.9-3.9)2.8 (1.4-6.6)