Case Report
Copyright ©2007 Baishideng Publishing Group Inc.
World J Gastroenterol. Nov 7, 2007; 13(41): 5512-5515
Published online Nov 7, 2007. doi: 10.3748/wjg.v13.i41.5512
Figure 2
Figure 2 A, B: Puncture of the bile duct via the duodenum under endosonographic guidance, followed by deployment of a plastic stent. C: Endoscopic view after stent placement.