Copyright
©2006 Baishideng Publishing Group Co.
World J Gastroenterol. Nov 28, 2006; 12(44): 7183-7187
Published online Nov 28, 2006. doi: 10.3748/wjg.v12.i44.7183
Published online Nov 28, 2006. doi: 10.3748/wjg.v12.i44.7183
Authors | Castellote et al | Kim et al | Butani et al | Sapey et al | Thévenot et al |
Dipsticks | Aution sticks | UriSCAN/Mutistix10SG | Multistix®10SG | Nephur test/ Multistix10SG | Multistix 8SG/Combur2test LN (combined result) |
Inclusion scale | ≥ 3 (PMN ≥ 250/mm3) | ≥ 3 (PMN ≥ 500/mm3) /≥ 3 (PMN ≥ 75/mm3) | ≥ 2 (PMN ≥ 70/mL mm3) | N/A | ≥ 3 (PMN ≥ 125/mm3) /≥ 2 (PMN ≥ 75/mm3) |
Sensitivity (%) | 89 | 67/50 | 89 | 88/65 | 89 |
Specificity( %) | 99 | 100/100 | 99 | 100/100 | 100 |
PPV (%) | 98 | 100/100 | 89 | 94/92 | 100 |
NPV (%) | 97 | 89/87 | 99 | 99/97 | 99 |
- Citation: Rerknimitr R, Rungsangmanoon W, Kongkam P, Kullavanijaya P. Efficacy of leukocyte esterase dipstick test as a rapid test in diagnosis of spontaneous bacterial peritonitis. World J Gastroenterol 2006; 12(44): 7183-7187
- URL: https://www.wjgnet.com/1007-9327/full/v12/i44/7183.htm
- DOI: https://dx.doi.org/10.3748/wjg.v12.i44.7183